Stair Layout
Menu

Stair building codes

The calculator can check three sets of rules. Open one to see its requirements and use the calculator with it.

Side by side

Main stair rules in three codes
RuleIRC 2021Part KDIN 18065
Riser height≤ 7 3/4 in150 mm – 220 mm140 mm – 200 mm
Tread depth (going)≥ 10 in220 mm – 300 mm230 mm – 370 mm
Pitch or step ruleNot checked herePitch, maximum ≤ 42.0° / Twice the rise plus the going (2R + G) 550 mm – 700 mmStep rule 2s + a 590 mm – 650 mm
Headroom≥ 80 in≥ 2,000 mm≥ 2,000 mm
Width≥ 36 inNot checked here≥ 800 mm
Nosing3/4 in – 1 1/4 inNot checked here≥ 260 mm

Limits are taken from the published documents. The official text is authoritative, and local authorities may adopt them with changes.

Common questions

Which code applies to my stairs?

The one adopted where the building stands. In the US that is usually the IRC as adopted by your state or city; in England, the Building Regulations with Approved Document K; in Germany, the state building code, which refers to DIN 18065 for stairs. Your local building office can confirm it.

Why does my country's code not appear?

This first version checks three codes. For other places, use the comfort mode and compare the results with your local rules yourself.