Part K stair regulations
Limits for private stairs from Approved Document K, the official guidance on stairs for the Building Regulations in England.
Approved Document K gives practical guidance on meeting the Building Regulations in England for stairs, ladders and ramps. A private stair is one intended to be used by only one dwelling.
In Approved Document K the going is measured from nosing to nosing, and the rise and going should be the same for every step of a flight.
What the calculator checks
| Rule | Limit | Reference |
|---|---|---|
| Rise | 150 mm – 220 mm | 1.3, Table 1.1 |
| Going | 220 mm – 300 mm | 1.3, Table 1.1 |
| Pitch, maximum | ≤ 42.0° | Table 1.1, note 1 |
| Twice the rise plus the going (2R + G) | 550 mm – 700 mm | Table 1.1, 2R + G |
| Headroom, minimum | ≥ 2,000 mm | 1.11, Diagram 1.3 |
| Headroom, minimum | ≥ 1,900 mm | 1.13, Diagram 1.4 |
| Headroom, minimum | ≥ 1,800 mm | 1.13, Diagram 1.4 |
| Riser height · Largest and smallest riser or tread in a flight | ≤ 0 mm | 1.5 |
| Tread depth (run) · Largest and smallest riser or tread in a flight | ≤ 0 mm | 1.5 |
Source: Approved Document K: Protection from falling, collision and impact (HM Government), section 1
Limits are taken from the published documents. The official text is authoritative, and local authorities may adopt them with changes.
A value in the link was not valid and has been set back to its default.
Your stairs
16 risers of 171 mm and 15 treads of 287 mm. Meets Part K. (Not checked)
- Risers
- 16
- Treads
- 15
- Riser height
- 171 mm
- Tread depth (run)
- 287 mm
- Tread board depth
- 312 mm
- Total run
- 4,307 mm
- Angle
- 30.8°
- 2R + G
- 630 mm
- Stringer length
- 5,016 mm
- Wood left below the cuts
- 153 mm
- First riser on the stringer
- 146 mm
These results are a planning aid. They do not replace approval from your local building authority, and they are not a structural design. Check the rules that apply where you build before you cut.
Code check: Part K
| Rule | Required | This layout | Result | Clause |
|---|---|---|---|---|
| Rise | 150 mm – 220 mm | 171 mm | Meets | 1.3, Table 1.1 |
| Going | 220 mm – 300 mm | 287 mm | Meets | 1.3, Table 1.1 |
| Twice the rise plus the going (2R + G) | 550 mm – 700 mm | 630 mm | Meets | Table 1.1, 2R + G |
| Pitch, maximum | ≤ 42.0° | 30.8° | Meets | Table 1.1, note 1 |
| Headroom, minimum | ≥ 2,000 mm | — | Not checkedEnter the headroom to check this rule. | 1.11, Diagram 1.3 |
| Riser height · Largest and smallest riser or tread in a flight | ≤ 0 mm | 0 mm | MeetsAll risers and treads in this layout are equal. On site, keep them within the tolerance. | 1.5 |
| Tread depth (run) · Largest and smallest riser or tread in a flight | ≤ 0 mm | 0 mm | MeetsAll risers and treads in this layout are equal. On site, keep them within the tolerance. | 1.5 |
Stringer layout
Cut the stringer from the bottom up. The first riser is shorter by the tread thickness so that all steps end up the same height.
Cut the first riser 146 mm high, which is the full riser less the tread thickness. The bottom of the stringer sits flat on the floor.
The top of the stringer meets the upper floor. Check the cut against your framing before you make it.
Measured square from the inside corner of a notch to the bottom edge of the board. Check the minimum your local rules or deck guide require.
Step-by-step marks
Measure every mark from the bottom of the stringer, not from the previous mark, so rounding does not add up.
| Step | Height from floor | Run from first riser | Along the stringer |
|---|---|---|---|
| 1 | 171 mm | 0 mm | 171 mm |
| 2 | 343 mm | 287 mm | 447 mm |
| 3 | 514 mm | 574 mm | 771 mm |
| 4 | 686 mm | 861 mm | 1,101 mm |
| 5 | 857 mm | 1,148 mm | 1,433 mm |
| 6 | 1,029 mm | 1,436 mm | 1,766 mm |
| 7 | 1,200 mm | 1,723 mm | 2,099 mm |
| 8 | 1,372 mm | 2,010 mm | 2,433 mm |
| 9 | 1,543 mm | 2,297 mm | 2,767 mm |
| 10 | 1,715 mm | 2,584 mm | 3,101 mm |
| 11 | 1,886 mm | 2,871 mm | 3,435 mm |
| 12 | 2,057 mm | 3,158 mm | 3,769 mm |
| 13 | 2,229 mm | 3,445 mm | 4,103 mm |
| 14 | 2,400 mm | 3,732 mm | 4,438 mm |
| 15 | 2,572 mm | 4,019 mm | 4,772 mm |
| 16 | 2,743 mm | 4,307 mm | 5,106 mm |
Heights include the full riser for every step. Subtract the tread thickness when you mark the first cut on the stringer itself.
Other numbers of risers
The same total rise divided into a different number of steps.
| Risers | Riser | Tread depth | Total run | Angle | 2R + G | Result | Use this |
|---|---|---|---|---|---|---|---|
| 15 | 183 mm | 264 mm | 3,699 mm | 34.7° | 630 mm | Meets code | |
| 16 | 171 mm | 287 mm | 4,307 mm | 30.8° | 630 mm | Meets code | |
| 17 | 161 mm | 300 mm | 4,800 mm | 28.3° | 623 mm | Meets code | |
| 18 | 152 mm | 300 mm | 5,100 mm | 26.9° | 605 mm | Meets code |
Calculated in your browser. Your measurements are not sent anywhere unless you share the link.
Other points in Approved Document K
In a loft conversion, headroom of 1.9 m at the centre of the stair width, falling to 1.8 m at the side, is acceptable where 2.0 m cannot be achieved.
With open risers, treads should overlap by at least 16 mm, and the openings should not let a 100 mm sphere pass through.
Wales, Scotland and Northern Ireland have their own building regulations and guidance.
These points are listed for reference. The calculator does not check them.
Common questions
What is the maximum pitch for stairs in a house in England?
42° for a private stair. A stair can meet the rise and going limits and still be too steep: a 200 mm rise with a 220 mm going gives 42.3°.
What rise and going are allowed for a private stair?
A rise between 150 and 220 mm and a going between 220 and 300 mm, with twice the rise plus the going between 550 and 700 mm, and a pitch of no more than 42°.
Does Part K apply in Scotland or Wales?
No. Approved Document K is guidance for England. Wales publishes its own Approved Documents, and Scotland and Northern Ireland have separate building regulations.
Related calculators
- Stair Calculator
Enter the total rise. The calculator works out risers, treads and the stringer, and checks each rule of the building code you choose.
- Stair Stringer Calculator
Enter the total rise and your tread size. You get the cut for every step, the first and last cuts, and a template you can print at full size.
- Stair Rise and Run Calculator
Enter the total rise to get riser height and tread depth, then use the table to compare comfortable combinations.
- Deck Stair Calculator
Measure from the top of the deck to the surface where the stairs will land. The calculator works out the steps and lays out the stringers.
- Stair Angle Calculator
Enter the total rise and, if you know it, the total run. The angle of the stairs is shown first, with the steps that produce it.